1. CHARGE PROCEDURES


Sun-Xtender Batteries are charged at the factory and are ready for installation when they are received.
  • While in storage they should be boost charged every 90 days or when the open circuit voltage drops below 2.08 V./cell (12.5 V. for a 12 volt battery).
  • The battery temperature should be 20 C. (68 F.) or higher.
  • Boost charge the battery using a regulated constant voltage charger.
  • Set the charge voltage to 2.37 to 2.40 V./cell (14.2 to 14.4 V. for a 12 volt battery).
  • Charge the battery until the charger reaches the 2.37 to 2.40 V./cell (14.2 to 14.4 for a 12 volt battery) and leave the battery on charge for an additional 4 to 6 hours before removing it from the charger.
  • Alternately, the battery can be charged to the voltage setting until the current from the charger drops to 0.5 A. per 100 Ampere Hour rating of the battery.


  • 2. CONDITIONING CHARGE

    Batteries that have not been boost charged and have been in storage for long periods (not over 9 months) or that have been operated in a partial or low state of charge for long periods (90 days or more) may need a conditioning charge.
  • Charge the battery at a constant current rate using the table below for the specific battery involved.
  • Charge the battery until its voltage remains constant or decreases slightly.
  • Remove the battery from charge. It is recommended that a reserve capacity discharge test be performed (instructions below) to insure that the battery capacity is at or above the recommended minimum 80% of its capacity.
  • After the test is completed, recharge the battery as described in Item 1.
  • During the conditioning charge process, the battery will get hot. If the battery container’s temperature exceeds 50 C. (122 F.) remove the battery from charge and contact Concorde.
  • reaches 115 F° [46 C°] while on charge.

    CONSTANT CURRENT CHARGE RATE TABLE
    12 VOLT BATTERIES   6 VOLT BATTERIES
    Part #
    Amps
      Part #
    Amps
    PVX-340T
    2
      PVX-1380T
    7
    PVX-420T
    2
      PVX-1680T
    8
    PVX-490T
    2
      PVX-1780T
    8
    PVX-560T 
    3
      PVX-2080T
    10
    PVX-690T
    3
      PVX-2160T
    10
    PVX-840T
    4
      PVX-2240L
    11
    PVX-890T
    4
      2 VOLT BATTERIES
    PVX-1040T
    5
      PVX-4140T
    19
    PVX-1080T
    5
      PVX-5040T
    24
    PVX-2120L
    10
      PVX-5340T
    24
    PVX-2580L
    12
      PVX-6240T
    30
          PVX-6480T
    30




    3. RESERVE CAPACITY TEST

    The procedure described below allows the Ampere Hour Capacity of the battery to be tested. This test will insure that the battery is capable of providing the necessary capacity to perform properly.
  • Charge the battery in accordance with paragraph 1, Charging Procedures, above.
  • With the battery temperature above 20 C. (68 F.) discharge the battery at 25 Amps to 1.75 V./cell (10.5 V. for a 12 volt battery).
  • Record the amount of time in minutes of full discharge.
  • If the battery fails to deliver 80% of its rated discharge time, the battery should be replaced.
  • The discharge times for each of the Sun-Xtender batteries are listed in the table below.


  • 25 A DISCHARGE MINUTES TIME
    12 VOLT BATTERIES            6 VOLT BATTERIES
    Part Number
    80%
    Rated
      Part Number
    80%
    Rated
    PVX-340T
    40
    50
      PVX-1380T
    194
    242 
    PVX-420T
    49
    61
      PVX-1680T
    238
    298 
    PVX-490T
    67
    84
      PVX-1780T
    253
    316 
    PVX-560T 
    77
    96
      PVX-2080T
    298
    372 
    PVX-690T
    97
    121
      PVX-2160T
    312
    390 
    PVX-840T
    119
    149
      PVX-2240L
    394
    492 
    PVX-890T
    126
    158
      2 VOLT BATTERIES
    PVX-1040T
    149
    186
      PVX-4140T
    581
    726 
    PVX-1080T
    156
    195
      PVX-5040T
    715
    894 
    PVX-2120L
    312
    390
      PVX-5340T
    758
    948 
    PVX-2580L
    403
    504
      PVX-6240T
    893
    1116 
     
      PVX-6480T
    936
    1170